Midas PRO Series Specifications Page 39

  • Download
  • Add to my manuals
  • Print
  • Page
    / 52
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 38
Diagnostics screen B-31
Midas Digital Consoles
Addendum B
The colour of each device, together with its link (if applicable), indicates its current
status, as shown in the following table.
Item Element Description
1 Console column This column contains boxes that represent the
internal processes of the PRO1 Control Centre, such
as the control surface, master controller, DSP, Audio
IO and GUI. If any of these develop an error
condition the colour of the boxes will change to red.
Clicking the DL271 DSP Board box will open a
Diagnostics Inspector window (see “About the
Diagnostics Inspector window” on page 32).
2 Link column This column shows the health of the physical
connection of each AES50-compatible device and the
PRO1 Control Centre. Clicking a link will open a
Diagnostics Inspector window (see “About the
Diagnostics Inspector window” on page 32).
3 Configured
column
This column shows any AES50 devices, such as a
IDL251 Audio System I/O, that have been detected as
connected to the system and are also configured for
the system. Clicking one of these devices will open a
Diagnostics Inspector window (see “About the
Diagnostics Inspector window” on page 32).
4 Unconfirmed
column
This column shows any AES50 devices, such as a
IDL251 Audio System I/O, that have been detected as
connected to the system, but have not been
configured during the patching procedure. Clicking
one of these devices will open a Diagnostics
Inspector window (see “About the Diagnostics
Inspector window” below). To configure a device, see
“Setting up the I/O rack devices” on page 39.
5 CONFIG button Opens the AES50 Device Configuration window
(see Figure 9 “Typical AES50 Device Configuration
window” on page 39)
State Description Unit status
Connection of
active link
Connection of
inactive link
Both the unit and
link are green
Good Good Good
Unit is green and
the link is red
Good Bad Not known
Unit is red and the
link is green
Malfunction Good Not known
Both the unit and
link are red
Not known Bad Bad