Menus 19
DL431 Mic Splitter
Operator Manual
4 48V Control
This menu lets you set the 48V phantom voltage source.
>> To select the 48V phantom voltage source for the unit
1 In programming mode, select menu 4 (see “To select a
menu” on page 13).
2 Press the up/down arrow buttons choose the source of
the 48V phantom voltage, for example, mic amp B.
3 Press SELECT.
5 AES50 Status menu
This menu lets you view/clear the AES50 status of the DL431 Mic Splitter.
>> To view/clear the AES50 status
1 In programming mode, select menu 5 (see “To select a
menu” on page 13).
2 Press the up/down arrow buttons to choose the AES50
display you want, for example, “AES50 B Status 5”.
3 Do one of the following:
To clear the values, press SELECT.
Note: You can only clear the X and Y values for
AES50 Regs when you see the message “Hold Sel
to clr” on line 2 of the display. This message
typically does not appear on Status 3 and 4
displays.
If you don’t want to clear the values, press MENU.